undefined
+
  • undefined

YFN7-12

The YFN7 (FN7)-12 series indoor AC high-voltage load switch is a gas-blast arc-extinguishing type high-voltage load switch combined with a fuse, designed for use in 50Hz, 12kV-rated three-phase AC power systems. It is specifically engineered to interrupt load currents and make or break short-circuit currents. The fuse-combined switch can reliably clear short-circuit faults while offering single-phase fuse tripping that results in simultaneous three-phase disconnection—a perfect solution for protecting lines, equipment, and transformers. Its performance fully complies with the standards GB 3804-2004 "High-Voltage AC Load Switches Rated from 3.6kV to 40.5kV" and GB 16926-2009 "High-Voltage AC Load Switch-Fuse Combination Units."

Category:

  • Product Description
  • Product Overview

    The YFN7 (FN7)-12 series indoor AC high-voltage load switch is a gas-blast arc-extinguishing type high-voltage load switch combined with a fuse, designed for use in 50Hz, 12kV-rated three-phase AC power systems. It is specifically engineered to interrupt normal load currents and make/clear short-circuit currents. The fuse-combined switch unit is capable of handling short-circuit currents and features single-phase fuse operation that triggers a three-phase trip, making it the ideal choice for protecting lines, equipment, and transformers. Its performance complies with GB3804-2004 "High-Voltage AC Load Switches Rated from 3.6kV to 40.5kV" and GB16926-2009 "High-Voltage AC Load Switch-Fuse Combination Units."

    Model Description

    Environmental operating conditions

    1. Altitude ≤ 1000 m;
    2. Ambient temperature range: -25°C to +40°C;
    3. The daily average relative humidity should not exceed 95%, and the monthly average should not surpass 90%.
    4. The surrounding air is not noticeably contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt spray;
    5. Areas free from fire and explosion hazards;
    6. Locations with seismic intensity not exceeding 8 degrees and slope no greater than 5°.
    Note: The above are the standard operating conditions according to GB/T 11022. For special application environments such as high altitudes, heavy salt spray, or extremely cold/heat conditions, the technical design can be modified and customized based on the above requirements.

    Main technical specifications

    Structural Features

    The multiple installation options for this high-voltage isolator switch meet a variety of customer requirements.
    A: Installation Methods — Top-entry wiring (straight installation), bottom-entry wiring (inverted installation), or wall-mounted installation with a wall-mounted operating mechanism.
    B: Operation Modes – Side-Panel Operation, Front-Panel Operation

    Operating mechanism

    Switch shape

Keywords:

YFN7-12